IEC60904-9-2020

5.4.3 
Classification for temporal instability 
5.4.3.1 
General 
The class of the solar simulator for temporal instability is given by the following: 
For STI: 
Class A+: Temporal instability 

0,25 %, as specified in Table 3. This classification can be 
only assigned if spectral match evaluation is performed according to Table 2. 
Class A: Temporal instability >0,25 % and 

0,5 %, as specified in Table 3. 
Class B: Temporal instability >0,5 % and 

2 %, as specified in Table 3. 
Class C: Temporal instability >2 % and 

10 %, as specified in Table 3. 
For LTI: 
Class A+: Temporal instability <1 %, as specified in Table 3. This classification can be only 
assigned if spectral match evaluation is performed according to Table 2. 
Class A: Temporal instability >1 % and 

2 %, as specified in Table 3. 
Class B: Temporal instability >2 % and 

5 %, as specified in Table 3. 
Class C: Temporal instability >5 % and 

10 %, as specified in Table 3. 
Copyrighted material licensed to University of Toronto by Clarivate Analytics (US) LLC, subscriptions.techstreet.com, downloaded on 2020-09-26 08:51:03 +0000 by University of Toronto User.
No further reproduction or distribution is permitted.


– 22 – 
IEC 60904-9:2020 © IEC 2020 
5.4.3.2 
Solar simulators for I-V measurement 
If a 3-channel measurement is performed for each I-V data point (PV device current, PV 
device voltage, irradiance) only STI will be relevant for classification and LTI will be 
informative but nevertheless has to be assessed and reported. 
The LTI value is a direct indicator for the required irradiance correction of the measured I-V 
curve. The use of incorrect I-V correction parameters is a source of measurement uncertainty. 
The larger the irradiance correction, the greater is the effect. Limitations for LTI in 
combination with I-V correction may be given in other IEC standards. Further uncertainty 
aspects are discussed in IEC TR 60904-14. 
If a 2-channel measurement per I-V data point is performed (PV device current, PV device 
voltage) LTI will be relevant for classification and STI is informative. 