SAfETy INSTruCTIONS

GrOuNDING INSTruCTIONS

This appliance must be grounded. In the event of an electrical short circuit, grounding reduces the risk of 

electric shock by providing an escape wire for the electric current. This oven is equipped with a cord that has 

a grounding wire with a grounding plug, which must be plugged into an outlet that is properly installed and 

grounded. Consult a qualified electrician or serviceman if uncertain about the ability to follow grounding 

instructions or if in doubt as to whether the appliance is properly grounded.



 X 

do not use an extension cord. If the power cord is too short, have a qualified electrician or 

 

serviceman install an outlet near the appliance.



 

WARNING: Improper grounding can result in risk of electric shock.

POWEr COrD rEPLACEMENT Or rEMOVAL

If the power cord is damaged, it must be replaced by the manufacturer, its service agent, or a similarly 

qualified person.

 

WARNING: If the oven is unplugged during service or maintenance, the user must be able to access and 



 

see the plug at all times to ensure that the oven remains unplugged. The plug must remain near the oven 

 

and cannot be placed behind another appliance or in another room.



PrECAuTIONS TO AVOID POSSIBLE EXPOSurE

TO EXCESSIVE MICrOWAVE ENErGy

(a)  Do not attempt to operate this oven with the door open since open-door operation can result in  

 

 



harmful exposure to microwave energy. It is important not to defeat or tamper with the safety  

 

 interlocks.



(b)  Do not place any object between the oven front face and the door or allow soil or cleaner residue to   

 

accumulate on sealing surfaces.



(c)  Do not operate the oven if it is damaged. It is particularly important that the oven door close  

 

 



properly and that there is no damage to the: (1) Door (bent), (2) hinges and latches (broken or  

 

 



loosened), (3) door seals and sealing surfaces.

(d)  The oven should not be adjusted or repaired by anyone except properly qualified service personnel.

rf INTErfErENCE CONSIDErATIONS

This oven generates radio frequency signals. This device has been tested and was determined to be in compli-

ance with applicable portions of FCC part 18 requirements and to the protection requirements of Council 

Directive 89/336/EEC on the approximation of the laws of the Member States relating to electromagnetic 

compatibility at the time of manufacture. However, some equipment with sensitivity to signals below these 

limits may experience interference.

If your equipment experiences interference:

a

Increase the physical separation between this oven and the sensitive equipment.



a

If the sensitive device can be grounded, do so following accepted grounding practices.

a

If battery-powered microphones are being affected, ensure that the batteries are fully charged.



a

Keep sensitive equipment on separate electrical circuits if possible.

a

Route intercom wires, microphone wires, speaker cables, etc. away from the oven.



 

SAVE THESE INSTruCTIONS




 

iii


SA

fET


y

 INST


ru

CTIONS


PrOTECTIVE EArTH (GrOuND) SyMBOL

 

 



This symbol identifies the terminal which is intended for connecting an external conductor for 

 

 



protection against electric shock in case of a fault, or the terminal of a protective earth (ground) 

  electrode. 

 

 

EQuIPOTENTIAL BONDING SyMBOL



  

This symbol identifies the terminals which, when connected together, bring the various parts of an 

 

 

equipment or of a system to the same potential, not necesarily being the earth (ground) potential, 



 

 

e.g. for local bonding.



SAVE THESE INSTruCTIONS


iv

SAfETy INSTruCTIONS

This page intentionally blank.



 

1

SPECI



fICATIONS

 AND


 INSTALLATION

Theory of Operation

Utilizing TurboChef’s patented technology to  

rapidly cook food without compromising quality, the 

i1 (models Soˇta, Soˇta Single Magnetron, Panini, and 

NGO) ovens provide superior cooking performance 

while requiring minimal space and energy consump-

tion. The control system precisely coordinates inde-

pendent top and bottom impinged airflow with top-

launched microwave to deliver product-specific results, 

and integral catalytic converters allow for UL®-certified 

ventless operation (see page 4 for details).

This manual includes instructions for installing, clean-

ing, and operating i1 ovens. If you have questions that 

are not addressed in this manual, contact Customer 

Support at 800.90TURBO (+1 214.379.6000) or your 

Authorized Distributor.

features 

  -  Capacitive touch screen with industrial-grade    

    tempered glass cover

  -  Manual mode for on-the-fly cooking

  -  Add from cookbook option that allows a user to  

    access and save TurboChef cookbook recipes

  -  Up to 10 selectable languages

  -  Integrated tutorials for daily operation 

    and maintenance

  -  Enhanced data logging for troubleshooting    

    assistance and learning which products are    

    being cooked and when

  -  Menu editing tools and USB/smart 

    card detection

  - WiFi ready for the connected kitchen

Dimensions

Oven Dimensions

Height: 25.0” (635 mm)

Width: 16.0” (406 mm)

Depth (footprint): 18.5” (470 mm)

Depth (door closed):  29.8” (757 mm)

Depth (door open): 39.1” (993 mm)

Oven Weight

Soˇta, Panini, and NGO: 170 lb. (77 kg)

Soˇta Single Magnetron: 135 lb. (61.2 kg)

Cook Cavity Dimensions

Height: 7.2” (183 mm)

Width: 12.5” (318 mm)

Depth: 10.5” (267 mm)

Volume: 0.54 ft

3

 (15.4 liters)



Clearances

Top: 5” (127 mm)

Sides: 2” (51 mm)

16.0”


(406 mm)

21.0”


(533 mm)

4.0”


(102 mm)

11.8”


(300 mm)

25.0”


(635 mm)

27.3”


(693 mm)

Approximate location

of cord and plug

2.5”


(64 mm)

18.5”


(470 mm)

4.2”


(107 mm)

10.7”


(272 mm)

25.9”


(658 mm)

2.5”


(64 mm)

39.1”


(993 mm)

figure 1: i1 Oven Dimensions

16.0”

(406 mm)


21.0”

(533 mm)


4.0”

(102 mm)


11.8”

(300 mm)


25.0”

(635 mm)


27.3”

(693 mm)


Approximate location

of cord and plug

2.5”

(64 mm)


18.5”

(470 mm)


4.2”

(107 mm)


10.7”

(272 mm)


25.9”

(658 mm)


2.5”

(64 mm)


39.1”

(993 mm)


16.0”

(406 mm)


21.0”

(533 mm)


4.0”

(102 mm)


11.8”

(300 mm)


25.0”

(635 mm)


27.3”

(693 mm)


Approximate location

of cord and plug

2.5”

(64 mm)


18.5”

(470 mm)


4.2”

(107 mm)


10.7”

(272 mm)


25.9”

(658 mm)


2.5”

(64 mm)


39.1”

(993 mm)



Yüklə 5,03 Mb.

Dostları ilə paylaş:
1   2   3   4   5   6   7   8   9   10   11




Verilənlər bazası müəlliflik hüququ ilə müdafiə olunur ©genderi.org 2024
rəhbərliyinə müraciət

    Ana səhifə